Household electrical load with a diversity factor. Sizing on connected load rather than diversified load overstates the requirement substantially, because everything is never switched on at once.
Also called: house load calculator, sanctioned load calculator.
Diversified load
5,220
5,220 W after a 60% diversity factor on a connected load of 8,700 W. That draws 23.89 A at 230 V, needing a 32 A main. The sanctioned load should be about 5.22 kW. Diversity reflects that appliances are not all on at once. Sizing on connected load oversizes the supply.
Connected load
8,700
Current draw
23.89
Recommended main breaker
32
Sanctioned load
5.22
Apparent power
5.5
On diversity
Diversity reflects that appliances are not all on at once. Sizing on connected load oversizes the supply.
On regulation
This is a sizing estimate. The applicable wiring or building regulation governs and overrides any figure here.
Connected load is the sum of everything installed. Diversity recognises that a household never runs every appliance simultaneously, and a factor of fifty to seventy percent is typical for domestic supply. The current follows from the diversified load divided by voltage and power factor, and the main breaker is sized above that. Sanctioned load from the utility is usually specified in kilowatts and set from the diversified figure rather than the connected one.
diversity accounts for the fact that everything is never on at once